  • infrared sensor refrigerant gas, R513a, R514a, R448, R410a, R407c, R410a, R404a, R407a, R32, R134a, R154, R22, R1234yf, R125, R123, R1233ZD(E)

    iR-gas R154 Refrigerant Gas Detector 0-1,000 ppm

    Meet our iR-gas R154 Refrigerant Gas Detector enabled with an Infrared Sensor

    Our R154 refrigerant gas detector with infrared sensor, “iR-gas” functionality is to detect the presence of the target refrigerant gas in the air surrounding it. This refrigerant gas detector with an enabled infrared sensor is designed to be connected to a GDA gas detection controller or similar Building Management System(BMS). This infrared sensor will control the alarm systems and/or ventilation to reduce gas loss and potentially harmful situations.

    Our R154 refrigerant gas detector contains a Non-Dispersive Infra-Red (NDIR) gas sensor and is operating via natural diffusion. This sensor is designed to give long service life under normal ambient operating conditions. Its sensor technology allows greater accuracy and lower cross-sensitivity to other gases, majorly reducing false readings when other gases are present.

    Our iR-gas refrigerant gas detector has the following technical features: Range: 0-1000 ppm; NDIR Sensor, Output: 4-20 mA, 0-20 mA, 0-5 VDC or 0-10 VDC, Alarm Relay, Power: 24 VDC 3-wire powered, Factory set alarm: 250 ppm, Factory Calibrated Output set to 4-20 mA.

  • infrared sensor refrigerant gas, R513a, R514a, R448, R410a, R407c, R410a, R404a, R407a, R32, R134a, R154, R22, R1234yf, R125, R123, R1233ZD(E)

    iR-gas R22 Refrigerant Gas Detector 0-1,000 ppm

    Meet our iR-gas R22 Refrigerant Gas Detector enabled with an Infrared Sensor

    Our R22 refrigerant gas detector with infrared sensor, “iR-gas” functionality is to detect the presence of the target refrigerant gas in the air surrounding it. This refrigerant gas detector with an enabled infrared sensor is designed to be connected to a GDA gas detection controller or similar Building Management System(BMS). This infrared sensor will control the alarm systems and/or ventilation to reduce gas loss and potentially harmful situations.

    Our R22 refrigerant gas detector contains a Non-Dispersive Infra-Red (NDIR) gas sensor and is operating via natural diffusion. This sensor is designed to give long service life under normal ambient operating conditions. Its sensor technology allows greater accuracy and lower cross-sensitivity to other gases, majorly reducing false readings when other gases are present.

    Our iR-gas refrigerant gas detector has the following technical features: Range: 0-1000 ppm; NDIR Sensor, Output: 4-20 mA, 0-20 mA, 0-5 VDC or 0-10 VDC, Alarm Relay, Power: 24 VDC 3-wire powered, Factory set alarm: 250 ppm, Factory Calibrated Output set to 4-20 mA.

  • infrared sensor refrigerant gas, R513a, R514a, R448, R410a, R407c, R410a, R404a, R407a, R32, R134a, R154, R22, R1234yf, R125, R123, R1233ZD(E)

    iR-gas R1234yf Refrigerant Gas Detector 0-1,000 ppm

    Meet our iR-gas R1234yf Refrigerant Gas Detector enabled with an Infrared Sensor

    Our R1234yf refrigerant gas detector with infrared sensor, “iR-gas” functionality is to detect the presence of the target refrigerant gas in the air surrounding it. This refrigerant gas detector with an enabled infrared sensor is designed to be connected to a GDA gas detection controller or similar Building Management System(BMS). This infrared sensor will control the alarm systems and/or ventilation to reduce gas loss and potentially harmful situations.

    Our R1234yf refrigerant gas detector contains a Non-Dispersive Infra-Red (NDIR) gas sensor and is operating via natural diffusion. This sensor is designed to give long service life under normal ambient operating conditions. Its sensor technology allows greater accuracy and lower cross-sensitivity to other gases, majorly reducing false readings when other gases are present.

    Our iR-gas refrigerant gas detector has the following technical features: Range: 0-1000 ppm; NDIR Sensor, Output: 4-20 mA, 0-20 mA, 0-5 VDC or 0-10 VDC, Alarm Relay, Power: 24 VDC 3-wire powered, Factory set alarm: 250 ppm, Factory Calibrated Output set to 4-20 mA.

  • infrared sensor refrigerant gas, R513a, R514a, R448, R410a, R407c, R410a, R404a, R407a, R32, R134a, R154, R22, R1234yf, R125, R123, R1233ZD(E)

    iR-gas R1234ze Refrigerant Gas Detector 0-1,000 ppm

    Meet our iR-gas R1234ze Refrigerant Gas Detector enabled with an Infrared Sensor

    Our R1234ze refrigerant gas detector with infrared sensor, “iR-gas” functionality is to detect the presence of the target refrigerant gas in the air surrounding it. This refrigerant gas detector with an enabled infrared sensor is designed to be connected to a GDA gas detection controller or similar Building Management System(BMS). This infrared sensor will control the alarm systems and/or ventilation to reduce gas loss and potentially harmful situations.

    Our R1234ze refrigerant gas detector contains a Non-Dispersive Infra-Red (NDIR) gas sensor and is operating via natural diffusion. This sensor is designed to give long service life under normal ambient operating conditions. Its sensor technology allows greater accuracy and lower cross-sensitivity to other gases, majorly reducing false readings when other gases are present.

    Our iR-gas refrigerant gas detector has the following technical features: Range: 0-1000 ppm; NDIR Sensor, Output: 4-20 mA, 0-20 mA, 0-5 VDC or 0-10 VDC, Alarm Relay, Power: 24 VDC 3-wire powered, Factory set alarm: 250 ppm, Factory Calibrated Output set to 4-20 mA.

  • infrared sensor refrigerant gas, R513a, R514a, R448, R410a, R407c, R410a, R404a, R407a, R32, R134a, R154, R22, R1234yf, R125, R123, R1233ZD(E)

    iR-gas R125 Refrigerant Gas Detector 0-1,000 ppm

    Meet our iR-gas R125 Refrigerant Gas Detector enabled with an Infrared Sensor

    Our R125 refrigerant gas detector with infrared sensor, “iR-gas” functionality is to detect the presence of the target refrigerant gas in the air surrounding it. This refrigerant gas detector with an enabled infrared sensor is designed to be connected to a GDA gas detection controller or similar Building Management System(BMS). This infrared sensor will control the alarm systems and/or ventilation to reduce gas loss and potentially harmful situations.

    Our R125 refrigerant gas detector contains a Non-Dispersive Infra-Red (NDIR) gas sensor and is operating via natural diffusion. This sensor is designed to give long service life under normal ambient operating conditions. Its sensor technology allows greater accuracy and lower cross-sensitivity to other gases, majorly reducing false readings when other gases are present.

    Our iR-gas refrigerant gas detector has the following technical features: Range: 0-1000 ppm; NDIR Sensor, Output: 4-20 mA, 0-20 mA, 0-5 VDC or 0-10 VDC, Alarm Relay, Power: 24 VDC 3-wire powered, Factory set alarm: 250 ppm, Factory Calibrated Output set to 4-20 mA.