The Gas Detection Australia range of fixed gas detectors and gas sensors are manufactured to order and comprise of electrochemical sensors for toxic and oxygen sensors along with a range of infra red based sensors for Carbon Dioxide and Refrigerant gases. For volatile organic compounds(VOC's), Photo ionization methods (PID) are utilized.
The GDA 2525 Carbon Monoxide (CO) gas sensor is a 2 wire 4-20 mA Loop Powered device. It has an electrochemical carbon monoxide sensor unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2526 Ammonia (NH₃) gas sensor is a 2 wire 4-20 mA Loop Powered device. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2527 Nitrogen Dioxide (NO₂) Gas Sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-30 ppm Nitrogen Dioxide. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2528 Oxygen gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-25% vol Oxygen. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2529 Hydrogen Sulphide gas sensor is a 2 wire 4-20 mA loop Powered device with a range of 0-50 ppm Hydrogen Sulphide. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2530 Sulphur Dioxide gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-20 ppm Sulphur Dioxide. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2535 Ethylene (C₂H₄) gas sensor is a 2 wire 4-20 mA Loop Powered device utilising an electrochemical Ethylene sensor unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2625 Carbon monoxide gas sensor is a further enhancement of the GDA 2525 Carbon monoxide gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2626 Ammonia gas sensor is a further enhancement of the GDA 2526 Ammonia gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2627 Nitrogen Dioxide gas sensor is a further enhancement of the GDA 2527 Nitrogen Dioxide gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2628 Oxygen gas sensor is a further enhancement of the GDA 2528 Oxygen gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2629 Hydrogen Sulphide gas sensor is a further enhancement of the GDA 2529 Hydrogen Sulphide gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2630 Sulphur Dioxide gas sensor is a further enhancement of the GDA 2530 Sulphur Dioxide gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 3100 Refrigerant Gas Detector uses the latest in NDIR techniques for detecting a wide range of refrigerant gases and is immune from cross sensitivity to other gases. In addition it is immune to changes in humidity and temperature with a longer lifespan then standard semiconductor sensors.
Designed, manufactured and supported locally in Australia.
The GDA 3160 is a low profile wall mounted refrigerant detector for use in offices and laboratories where a gas sensor needs to appear non obtrusive. The sensor uses the lastest in NDIR techniques for detecting a wide range of refrigerant gases and is therefore immune from cross sensitivity to other gases.
Designed, manufactured and supported locally in Australia.
The GDA 3300 Sulphur Hexafluoride (SF₆) detector provides reliable long term detection of SF₆ gas at low levels. It has a configurable analog output of 4-20 mA; 0-20 mA; 0-5 V; 0-10 V. There is also a volt free relay which can be user programmed to operate anywhere within the sensor range. The unit is powered from 24 VDC.
Designed and manufactured locally in Australia.
The GDA 4350 is a 3 wire Non Dispersive Infra red (NDIR) Carbon Dioxide (CO₂) sensor. It gives a 4-20 mA, 0-20 mA, 0-5 V or 0-10 V o/p over the range of the sensor. Low Temperature version available.
Designed, manufactured and supported locally in Australia.
The GDA 4360 is a 3 wire 4-20 mA Non Dispersive Infra red (NDIR) Carbon Dioxide (CO₂) Sensor. It gives a 4-20 mA o/p over the range of the sensor. Designed for applications where low profile intrusion into a room space is required.
Designed, manufactured and supported locally in Australia.
The GDA7228 Flush Mount Oxygen gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-25% vol Oxygen.
Designed, manufactured and supported locally in Australia.
The GDA 40125 Gas Detection Controller is a standalone gas detector unit with inbuilt display, sounder, flasher, relays and alarm driver. Available in the full range of GDA 2500 series electrochemical sensors which are temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 40127 Carbon Dioxide Gas Detection Controller is a standalone gas detector unit with inbuilt display, sounder, flasher, relays and alarm driver using an non dispersive infra red sensor.
Designed, manufactured and supported locally in Australia.
SI-100C is a IEC Ex explosion proof gas sensor ready to installed hazardous and non-hazardous areas to prevent gas hazards caused oxygen depletion, toxic gas or combustible gas. Available to detect over 25 different gas types, see Ordering Information for details.
Locally Technically Supported by Gas Detection Australia
The GDA 2000Ex Flammable Gas Detector is certified for use in Zone 1 Hazardous areas within Australia.
Locally Technically Supported by Gas Detection Australia
GDA 2000Tx Explosion Proof (IEC Ex) Toxic and Oxygen Gas Detector is certified for use in Zone 1 Hazardous areas within Australia.
Locally Technically Supported by Gas Detection Australia
The GDA 2000VOC is an explosion proof (IEC Ex) certified VOC gas detector using PID technology as means of detection.
Locally Technically Supported by Gas Detection Australia
This Infra red sensor is certified for use in Zone 1 Hazardous areas within Australia.
Locally Technically Supported by Gas Detection Australia
SI-100 is an IEC Ex fixed gas detector installed where potential gas hazard occur to measure and monitor oxygen, toxic gas and combustible gas. Utilising magnetic switchs so that Hot Work permit not required for calibration.
Locally Technically Supported by Gas Detection Australia
The GDA 4500 is designed to be used where sensors are placed in areas that are difficult to gain access such as pits and elevated areas.
Designed, manufactured and supported locally in Australia.
The GD 4508/16 is a 1 to 16 point gas sampling system for use in commercial buildings to control fresh air make up in rooms relative to external fresh air. Available for: Carbon Monoxide (CO), Oxygen (O₂) or Carbon Dioxide (CO2).
Designed, manufactured and supported locally in Australia.
Designed to be used where areas that are difficult to gain access due to distance or toxic environment. As well as to detect greater ranges of toxic gases using advanced Pyrolyzer technology converting electrochemically inactive gases to easily detected gases.
The GDA 2560 Flammable gas sensor [Hydrogen, Methane, Butane, Propane, Acetylene, and Ammonia] is a 3 wire (24 VDC) 4-20 mA device. This gas sensor is designed to be used in Non-hazardous areas. It has an electro-resistive catalytic sensing element which is temperature controlled and easily replaceable.
Designed, manufactured and supported locally in Australia.
Discontinued Product
The GDA 4350 Pump is designed to be used where diffusion sensors are impractical due to environmental or wash down requirements. An advanced 3 wire Non Dispersive Infra red (NDIR) Carbon Dioxide sensor giving a 4-20 mA, 0-20 mA, 0-5 V or 0-10 V o/p over the range of the sensor. Low Temperature version available.
Designed, manufactured and supported locally in Australia.