The GDA 40126 Gas Detection Controller is a standalone gas detector unit with inbuilt display, sounder, flasher, relays and alarm driver. Available for Flammable gases such as LNG, LPG, Propane, Hydrogen, Acetylene, Solvents, and other flammable vapours. Designed to be used in Non-hazardous areas with the GDA 2500 series easily replaceable sensor modules.
Designed, manufactured and supported locally in Australia.
This product is being replaced by the SENKO SI-100-009 Combustable Sensor
The GDA 40126 has 2 user relays which can be programed to operate at any level within the gas detectors operational range as well as an independent fail safe fault relay. The unit's alarm state is indicated by the display and by flashing LEDs additionally there is an o/p to drive a 24 VDC sounder / flasher (AVR-20) all of which can be muted from the front panel.
Poisoning: GDA sensors are designed to operate in a wide range of harsh environments and conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage and operation.
Made in Australia and Supported in Australia
Sewage Treatment Plant Monitoring | The presence of Hydrogen Sulphide can be detected by using the Gas Detection Australia GDA 2529 gas sensor to detect leaks of Hydrogen Sulphide and evoke deodorisation plant. The SI-100C gas sensor can be used to monitor for leaks of LEL levels of methane gas. In digester applications Carbon dioxide can be detected using the GDA 4350 Designed, Manufactured and Supported in Australia. |
Specification Name | Specification Value |
---|---|
Detectable Gases | Flammable Gas |
Detectable Gas Ranges | 0-100% LEL of selected Gas |
Power Requirements | +24 VDC |
Output Types | 2 x SPCO relays (alarm), 1 x Fault relay SPCO; 4-20mA . optional MODBUS |
Power Consumption | 2.5W |
Output Specifications | Relays 220v , 1 A , non inductive |
Connection | Plug in connector |
Wiring | min 0.75mm2 |
Operating Temperature | -10 - 40°C |
Operating Humidity | 5% to 95% RH peak non condensing |
Accuracy of Reading | 0.5% of reading + 1% FSD |
Warm Up Time | 30 seconds |
Response Time | T90= 15 seconds |
Zero Drift | < 0.5% per 30 days |
Calibration Drift | <5% pa @ SATP |
Sensor Technology | Catalytic Cell |
Calibration Requirement | Annually with 6 monthly functional tests if senor operated at SATP |
Warranty | 12 months from date of dispatch |
Dimensions | 155 x 130 x 65 mm (L, W, D) |
Enclosure Material | ABS plastic |
Enclosure Rating | IP53 |
Cable Entry | User provided |
![]() |
GDA 40126 Flammable Gas Detector
|
![]() |
||
---|---|---|---|---|
Part Number | Gas | Range | Replacment Sensor Module | |
40126-001 | Methane (CH₄) | 0-100% LEL | 2560-001M | |
40126-002 | Propane (C₃H₈) | |||
40126-003 | Hydrogen (H₂) | 2560-014H | ||
40126-004 | Acetylene (C₂H₂) | 2560-013A | ||
40126-005 | General Solvents, IPA | |||
40126-006 | No Sensor Module Fitted | |||
|
Accessories |
|||
Part Number | Image | Description | ||
4012X-001 | GDA 4012X Series RS485 Modbus Output Addon Card | |||
GC01-001 | ![]() |
Gassing Cap with 500mm Length vinyl tubing | ||
PSP1-24-075 | ![]() |
Australian Mains Plugpack Power Supply. Output: 0.75 A @ 24 VDC | ||
PSE | ![]() |
Enclosed 24 VDC Power Supply |
The PSU P24 is an AC-DC plugpack power supply with an output of 24 VDC at 0.75A. The plugpack has a 3m cable with a 2.1 mm DC plug.
This sounder/flashers operates at 24VDC. The sounder can be permanently disabled so that unit acts as a flasher only. These units are designed for internal use. These are available in Red or Amber.
To test and maintain accuracy gas detection systems require regular testing and calibration. GDA can provide you with a complete line of calibration equipment to calibrate all of our gas sensors and detectors. Our calibration gas cylinders all come with N.I.S.T. certification and ISO 17025 approval so you can be confident that you will receive gas with the highest accuracy levels.