Cryogenic freezing using liquid Nitrogen poses a problem of oxygen depletion. The GDA 2528 oxygen gas sensor offers a cost effective method of detection and low cost of maintenance. For standalone cyro-storage chambers housed in laboratories, the storage area can be monitored for oxygen depletion by the standalone GDA 40125 system.
The GDA 2528 Oxygen gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-25% vol Oxygen. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 2628 Oxygen gas sensor is a further enhancement of the GDA 2528 Oxygen gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
The GDA 4350 is a 3 wire Non Dispersive Infra red (NDIR) Carbon Dioxide (CO₂) sensor. It gives a 4-20 mA, 0-20 mA, 0-5 V or 0-10 V o/p over the range of the sensor. Low Temperature version available.
Designed, manufactured and supported locally in Australia.
The GDA 4360 is a 3 wire 4-20 mA Non Dispersive Infra red (NDIR) Carbon Dioxide (CO₂) Sensor. It gives a 4-20 mA o/p over the range of the sensor. Designed for applications where low profile intrusion into a room space is required.
Designed, manufactured and supported locally in Australia.
The GDA7228 Flush Mount Oxygen gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-25% vol Oxygen.
Designed, manufactured and supported locally in Australia.
The GDA 40125 Gas Detection Controller is a standalone gas detector unit with inbuilt display, sounder, flasher, relays and alarm driver. Available in the full range of GDA 2500 series electrochemical sensors which are temperature compensated and easily replaceable.
Designed, manufactured and supported locally in Australia.
This is a flush wall mounted (Clipsal GPO) single channel control unit. It interfaces to all the GDA a series of 4-20mA sensors. There are 3 relay o/p’s, Alarm 1, 2, and fault. These relays are SPCO. The backlit LCD display indicates current gas concentration and alarm status. There is an internal sounder which can be muted from the front panel. The unit requires 24v dc.
Designed, manufactured and supported locally in Australia.
The GDA 4020 control unit has 2 x 4-20 mA i/p with 3 associated programmable relay alarm levels per sensor. There is an independent fault relay. There are 3 x analog o/p’s which can be configured for either channel as 4-20 mA, 0-20 mA, 0-5 V or 0-10 V. The controller has an isolated RS485 o/p which can be configured to drive modbus or an interface to the M2001 mimic panel. All configurations are carried out via the front panel push buttons. The unit requires 24 VDC.
Designed, manufactured and supported locally in Australia.
The GDA 4080 Gas Detection Controller is designed to be to take up to eight sensor inputs and display the gas readings of the individual sensors. The multi-colour display will indicate the alarm status, levels and faults.
Designed, manufactured and supported locally in Australia.
The GDA 2400 control unit caters for up to 8 GDA Sensors. The controller selects the highest reading from the sensors and displays the highest reading and is used when all the gas sensors are the same type. It is particularly useful in Periphery monitoring and Car park ventilation control.
Designed, manufactured and supported locally in Australia.
The M2001 is a low profile flush wall mounted mimic panel. These units are used on multi entry rooms so that users may view the gas levels and alarm status of each entry point for entering the room, used in conjunction with the GDA 4020, GDA 2400 or GDA 4500 control unit.
Designed, manufactured and supported locally in Australia.
The GDA 74001 is a low profile flush wall mounted mimic panel. These units are used on multi entry rooms so that users may view the gas levels and alarm status of each entry point for entering the room The 74001 is used in conjunction with the GDA 4080 control unit.
Designed, manufactured and supported locally in Australia.
The GDA 74002 is a Extended Mimic Large Character Display . These are designed so that users may view the gas level and alarm status clearly from any point. The colour of the LED back light changes depending on the alarm state of the GDA 4080 control unit.
Designed, manufactured and supported locally in Australia.
The GDA Dual Channel Repeater Panel allows for simple replication of the alarm and system status of all GDA gas detection controllers by visual and auditory indicators.
Designed, manufactured and supported locally in Australia.
The MS001 uses one of the alarm relays from a GDA gas detection controller to drive the AVR-20R/YM sounder & flasher. The sounder- flasher can be muted by incorporating the MS001 into the output switched 24 VDC from the control panel.
Designed, manufactured and supported locally in Australia.
This sounder/flashers operates at 24VDC. The sounder can be permanently disabled so that unit acts as a flasher only. These units are designed for internal use. These are available in Red or Amber.
Gas Emergency Information Signs / Gas Alarm Signage