GDA 2526 : Ammonia Gas Sensor

The GDA 2526 Ammonia gas sensor is a 2 wire 4-20 mA Loop Powered device. It has an electrochemical sensing unit which is temperature compensated and easily replaceable.

Designed, manufactured and supported locally in Australia.

GDA 2528 : Oxygen Gas Sensor

The GDA 2528 Oxygen gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-25% vol Oxygen. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.

Designed, manufactured and supported locally in Australia.

GDA 2626 : Ammonia Gas Sensor with Voltage Output

The GDA 2626 Ammonia gas sensor is a further enhancement of the GDA 2526 Ammonia gas sensor that allows AC and DC operation. It has an electrochemical gas sensing unit which is temperature compensated and easily replaceable.

Designed, manufactured and supported locally in Australia.

GDA 3100 : Refrigerant Gas Detector

The GDA 3100 Refrigerant Gas Detector detects a wide range refrigerant gases (R22, R123, R134a, R404, R410 etc.) with a range of 0-1000ppm. Each dectector is calibrated to a specific gas type. It has a configurable analog output of 4-20 mA; 0-20 mA; 0-5 V; 0-10 V. There is also a volt free relay which can be user programmed to operate anywhere within the sensor range. The unit is powered from 24 VDC.

Designed, manufactured and supported locally in Australia.

GDA 4350 : Carbon Dioxide Gas Sensor

The GDA 4350 is a 3 wire Non Dispersive Infra red (NDIR) Carbon Dioxide sensor. It gives a 4-20 mA, 0-20 mA, 0-5 V or 0-10 V o/p over the range of the sensor. Low Temperature version available.

Designed, manufactured and supported locally in Australia.

GDA 7228 : Flush Mount Oxygen Gas Sensor

The 7228 Flush Mount Oxygen gas sensor is a 2 wire 4-20 mA Loop Powered device with a range of 0-25% vol Oxygen.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

GDA 40127 : Carbon Dioxide Gas Detection Controller

The GDA 40127 Carbon Dioxide Gas Detection Controller is a standalone gas detector unit with inbuilt display, sounder, flasher, relays and alarm driver using an non dispersive infra red sensor.

Designed, manufactured and supported locally in Australia.

GDA 4020 : Two Channel Gas Detection Controller

The GDA 4020 control unit has 2 x 4-20 mA i/p with 3 associated programmable relay alarm levels per sensor. There is an independent fault relay. There are 3 x analog o/p’s which can be configured for either channel as 4-20 mA, 0-20 mA, 0-5 V or 0-10 V. The controller has an isolated RS485 o/p which can be configured to drive modbus or an interface to the M2001 mimic panel. All configurations are carried out via the front panel push buttons. The unit requires 24 VDC.

Designed, manufactured and supported locally in Australia.

GDA 4080 : 8 Channel Gas Detection Controller

The GDA 4080 Gas Detection Controller is designed to be to take up to 8x 4-20 mA sensor inputs and display the gas readings of the individual sensors. The multi-colour display will indicate the alarm status, levels and faults.

Designed, manufactured and supported locally in Australia.

GDA 74001 : Extended Mimic Panel

The GDA 74001 is a low profile flush wall mounted mimic panel. These units are used on multi entry rooms so that users may view the gas levels and alarm status of each entry point for entering the room The 74001 is used in conjunction with the GDA 4080 control unit.

Designed, manufactured and supported locally in Australia.

M2001 : Flush Mount Mimic Panel

The M2001 is a low profile flush wall mounted MIMIC panel. These units are used on multi entry rooms so that users may view the gas levels and alarm status of each entry point for entering the room The M2001 is used in conjunction with the GDA 4020 AND GDA 2400 control unit. The M2001 derives its power and RS485 communications from the 4020/ 2400. The unit’s backlit LED display shows the real time concentration of the gas sensors connected to the 4020/ 2400 and any alarms that occur. The M2001 has an inbuilt sounder which can be muted from the front panel. The unit has two alarm relays which activate and deactivate in conjunction with the alarm status of the 4020 and 2400 control panel.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

MS001 : Flush Mount Mute Switch

The MS001 uses one of the alarm SPCO relays from the GDA 4020, GDA 4011, or GDA 2400 to drive the AVR-20R/YM sounder- flasher. The sounder- flasher can be muted by incorporating the MS001 into the o/p switched 24 VDC from the control panel. The sounder will sound when a gas alarm occurs and continue sounding until either the alarm level falls below its threshold value or the MS001 button is pressed. The Mute function automatically resets when the alarm condition terminates.

DESIGNED, MANUFACTURED and SUPPORTED by GAS DETECTION AUSTRALIA.

AVR 20 : Alarm Flasher and Sounder

This sounder/flashers operates at 24VDC. The sounder can be permanently disabled so that unit acts as a flasher only. These units are designed for internal use. These are available in Red or Amber.

Signage : Gas Emergency Information Signs/Gas Alarm Signage

Gas Emergency Information Signs / Gas Alarm Signage