• Monday – Thursday 8:00 am – 5:00 pm Friday 8:00 am to 4:00 pm

Tango TX2

Protect workers, reduce false alarms, and spend less time managing your gas detector fleet with the Tango TX2 Two-Gas Monitor.

View Quote List

Need Assistance? 1300 432 937

Protect workers, reduce false alarms, and spend less time managing your gas detector fleet with the Tango TX2. The Tango TX2 is the most accurate two-gas monitor featuring individual sensors that increase alarm accuracy. A two-year runtime and replaceable battery simplify gas detection management by eliminating the need for charging infrastructure.

Warranty

Guaranteed for Life™. Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). CO and H2S sensors are warranted for three years. All other sensors are warranted for two years.

Diplay/Readout

Segment liquid crystal display (LCD)

Keypad

Two buttons

Case Material

Case top: Polycarbonate with a protective rubber overmold Case bottom: Conductive polycarbonate

Alarms

Three strobe-emitting visual alarm LEDs (two red; one blue) 100 decibel (dB) audible alarm at a distance of 10 cm (3.94 in); Vibration alarm

Dimensions

99 x 51 x 35 mm (3.9 x 2.0 x 1.4 in)

Weight

126.0 g (4.4 oz)

Temperature Range

-40 °C to 50 °C (-40 °F to 122 °F) **

Humidity Range

15% to 95% Non-condensing (continuous)

Sensors

CO, CO/H2, HCN, H2S, NH3 NO2, SO2 – Electrochemical sensor technology

Sensor Measuring Ranges

Ammonia (NH3): 0to 500 ppm in 1 ppm increments Carbon Monoxide (CO): 0 to 1,000 ppm in 1 ppm increments Carbon Monoxide (CO/H2 low): 0 to 1,000 ppm in 1 ppm increments Hydrogen Cyanide (HCN): 0 to 30 ppm in 1 ppm increments Hydrogen Sulfide (H2S): 0to 500.0 ppm in 0.1 ppm increments Nitrogen Dioxide (NO2): 0to 150.0 ppm in 0.1 ppm increments Sulfur Dioxide (SO2): 0to 150.0 ppm in 0.1 ppm increments

Battery

3.6 V Primary lithium-thionyl chloride (Li-SOCl2); 1.5AH, 2/3AA; replaceable; non rechargeable; always on; up to 2-year run time depending on operating conditions

Data Logging

3 months at 10-second intervals

Event Logging

60 alarm events