• Monday – Thursday 8:00 am – 5:00 pm Friday 8:00 am to 4:00 pm

GasBadge Pro

Built to Industrial Scientific’s highest quality and reliability standards, GasBadge® Pro provides a lifetime of gas hazard protection with more features than any other single gas monitor available.

View Quote List

Need Assistance? 1300 432 937

Built to Industrial Scientific’s highest quality and reliability standards, GasBadge® Pro provides a lifetime of gas hazard protection with more features than any other single gas monitor available. Interchangeable “smart” sensors enable the GasBadge Pro to be quickly adapted to monitor unsafe levels of oxygen or any one of the following toxic gases: carbon monoxide, hydrogen sulfide, nitrogen dioxide, sulfur dioxide, chlorine, chlorine dioxide, phosphine, ammonia, hydrogen cyanide and hydrogen.

Warranty

Guaranteed for Life™ – Instrument is warranted for as long as supported by Industrial Scientific Corporation (excluding sensors, batteries, and filters). CO,H2S, and O2 sensors are warranted for 2 years. All other sensors warranted for1 year

Case Material

Rugged, water-resistant polycarbonate shell with protective concussion-proof overmold. RFI resistant.

Dimensions

9.4 x 5.08 x 2.79 mm (3.7 x 2 x 1.1 in )

Weight

85g (3oz)

Sensors

CO, H2S, O2, NO2, SO2, NH3, CI2,CIO2,PH3, HCN, H2, CO/H2Low

Sensor Measuring Ranges

CO: 0-1,500 ppm in 1 ppm increments CO/H2 low: 0-1,500 ppm in 1 ppm increments H2S: 0-500 ppm in 0.1 ppm increments O2: 0-30% by vol in 0.1% increments NO2: 0-150 ppm in 0.1 ppm increments SO2: 0-150 ppm in 0.1 ppm increments NH3: 0-500 ppm in 1 ppm increments Cl2: 0-100 ppm in 0.1 ppm increments ClO2: 0-1 ppm in 0.01 ppm increments PH3: 0-10 ppm in 0.01 ppm increments HCN: 0-30 ppm in 0.1 ppm increments H2: 0-2,000 ppm in 1 ppm increments

Display

Custom LCD with graphical icons for easy use; Segmented display for direct gas readings; Backlight for low light conditions; “Go/No Go” display mode; Peak reading indication

Alarms

User selectable low and high alarms Ultra-bright LEDs, loud audible alarm (95 dB) and vibrating alarm

BATTERY RUN TIME

User replaceable 3V, CR2 Lithium battery, 2,600 hour run time, typical

Data Logging

1 year continuous storage of data

Event Logged

Continually on. Logs last 15 alarm events, stamping how long ago the event occurred, the duration of the event, and the peak reading seen during the event. Event-logger can be viewed on PC or printed directly from the instrument to an infrared printer.

Temperature Range

-40 ºC to 60 ºC (-40 ºF to 140 ºF), typical

Humidity Range

0% to 99% RH (non-condensing), typical

IP Rating

Third-party certified IP64